吲哚菁绿(ICG)作为一种荧光染料,在近红外光激发下能够发出荧光,从而在手术过程中提供高对比度
的图像。这不仅提高了手术的精确性和安全性,还减少了手术时间和术后并发症的风险,因此这项技术为胸外科医
生提供了极大帮助,包括肺结节定位、肺段间平面识别、胸导管淋巴造影、前哨淋巴结定位等方面的应用。本文基
于国内外现有研究报道及实际临床案例,综合论述了吲哚菁绿(ICG)在胸外科手术中的多种用途。

关键词


吲哚菁绿;荧光染色;胸外科

全文:

PDF


参考


[1]Hulscher JB, Tijssen JG, Obertop H, van Lanschot

JJ (2001) Transthoracic versus transhiatal resection for

carcinoma of the esophagus: a meta-analysis.Ann Thorac Surg

72(1):306–313.

[2]De Grand AM, Lomnes SJ, Lee DS, Pietrzykowski

M, Ohnishi S,Morgan TG, et al. Tissue-like phantoms for

near-infrared fluorescence imaging system assessment and the

training of surgeons. J Biomed Opt. 2006;11:014007.

[3]ICHINOSE J,KOHNO T,FUJIMORI S,et al. Efficacy

and complications of computed tomography-guided hook wire

localization[J]. Ann Thorac Surg,2013,96(4):1203-1208.

[4]Z.D. Zhang, H.L. Wang, X.Y. Liu, F.F. Xia, Y.F.

Fu.Methylene blue versus coil-based computed tomography_xfffe_guided localization of lung nodules.Thorac Cardiovasc Surg,

68 (6) (2020), pp. 540-544.

[5]王冲,刘洋,杨磊,等.CT引导下术前经皮肺穿

刺注射吲哚菁绿定位肺内小结节和磨玻璃结节有效性和安

全性分析 [J].中华医学杂志,2020,100(7):538-540.

[6]C.J. Chang, C.H. Lu, X. Gao, H.Y. Fang, Y.K. Chao.

Safety and efficacy of cone-beam computed tomography_xfffe_guided lung tumor localization with a near-infrared marker: a

retrospective study of 175 patients.Life, 12 (4) (2022).

[7 ]O k u s a n y a OT, H o lt D, H eitj a n D, et a l.

Intraoperative near-infrared imaging can identify pulmonary

nodules. Ann Thorac Surg 2014;98:1223-30.

[8]Kim HK, Quan YH, Choi BH, et al. Intraoperative

pulmonary neoplasm identification using near-infrared

fluorescence imaging. Eur J Cardiothorac Surg 2016;49:1497-

502.

[9]Y. Mao, C. Chi, F. Yang, et al. The identification

of sub-centimetre nodules by near-infrared fluorescence

thoracoscopic systems in pulmonary resection surgeries.Eur J

Cardio Thorac Surg, 52 (6)(2017 Dec 1), pp. 1190-1196.

[10]QUAN Y H,OH C H,JUNG D,et al. Evaluation

of intraoperative nearinfrared fluorescence visualization of

the lung tumor margin with indocyanine green inhalation[J].

JAMA Surg,2020,155(8):732-740.

[11]K. Wang, W. Huang, X. Chen, et al. Efficacy of

near-infrared fluorescence video-assisted thoracoscopic

surgery for small pulmonary nodule resection with

indocyanine green inhalation: a randomized clinical trial.Ann

Surg Oncol, 30 (9) (2023 Sep), pp. 5912-5922.

[12]J.D. Predina, A.D. Newton, C. Corbett, et al.

160

Near-infrared intraoperative imaging for minimally invasive

pulmonary metastasectomy for sarcomas.J Thorac Cardiovasc

Surg, 157 (5) (2019), pp. 2061-2069.

[13]Misaki N, Chang SS, Gotoh M, et al. A novel

method for determining adjacent lung segments with infrared

thoracoscopy. J Thorac Cardiovasc Surg 2009;138:613-8.

[14]Pardolesi A, Veronesi G, Solli P, et al. Use

of indocyanine green to facilitate intersegmental plane

identification during robotic anatomic segmentectomy. J

Thorac Cardiovasc Surg 2014;148:737-8.

[15]M. Mun, S. Okumura, M. Nakao, Y. Matsuura,

K. Nakagawa.Indocyanine green fluorescence-navigated

thoracoscopic anatomical segmentectomy.J Vis Surg, 3 (2017),

p. 80.

[16]Y. Matsuura, M. Mun, J. Ichinose, M. Nakao,

K. Nakagawa, S. Okumura.Recent fluorescence-based

optical imaging for video-assisted thoracoscopic surgery

segmentectomy.Ann Transl Med, 7 (2) (2019), p. 32.

[17]M. Yotsukura, Y. Okubo, Y. Yoshida, K. Nakagawa,

S.I. Watanabe.Indocyanine green imaging for pulmonary

segmentectomy.JTCVS Tech, 6 (2021), pp. 151-158.

[18]Kubik S (1973) Anatomie des Lymphsystems

[Anatomy of the lymphatic system]. Radiol Clin Biol

42(4):243–257.

[19]S. Brinkmann, W. Schroeder, K. Junggeburth,

et al. Incidence and management of chylothorax after Ivor

Lewis esophagectomy for cancer of the esophagus.J Thorac

Cardiovasc Surg, 151 (5) (2016), pp. 1398-1404.

[20]Bryant AS, Minnich DJ, Wei B, Cerfolio RJ (2014)

The incidence and management of postoperative chylothorax

after pulmonary resection and thoracic mediastinal lymph

node dissection. Ann Thorac Surg 98(1):232–237.

[21]Cho HJ, Kim DK, Lee GD, Sim HJ, Choi SH, Kim

HR, Kim YH, Park SI (2014) Chylothorax complicating

pulmonary resection for lung cancer: effective management

and pleurodesis. Ann Thorac Surg 97(2):408–413.

[22]Stange S, Sziklavari Z (2019 ) Systematische

Übersichtsarbeit: moderne Behandlungsverfahren beim

postoperativen Chylothorax [Modern treatment options for

postoperative Chylothorax: a systematic review]. Zentralbl

Chir 144(3):290–297.

[23]Kamiya K, Unno N, Konno H (2009) Intraoperative

indocyanine green fluorescence lymphography, a novel

imaging technique to detect a chyle fistula after an

esophagectomy: report of a case. Surg Today 39(5):421–424.

[24]F. Yang, J. Zhou, H. Li, et al. Near-infrared

fluorescence-guided thoracoscopic surgical intervention for

postoperative chylothorax.Interact Cardiovasc Thorac Surg,

26 (2) (2018), pp. 171-175.

[25]T.G. Barnes, T. MacGregor, B. Sgromo, N.D.

Maynard, R.S. Gillies.Near infra-red fluorescence

identification of the thoracic duct to prevent chyle leaks

during oesophagectomy.Surg Endosc, 36 (7) (2022), pp.

5319-5325.

[26]Vecchiato M, Martino A, Sponza M, Uzzau A,

Ziccarelli A, Marchesi F, Petri R (2020) Thoracic duct

identification with indocyanine green fluorescence during

minimally invasive esophagectomy with patient in prone

position. Dis Esophagus 33(12):doaa030.

[27]YAMASHITA S,TOKUISHI K,MIYAWAKI M,et al.

Sentinel node navigation surgery by thoracoscopic fluorescence

imaging system and molecular examination in non-small cell

lung cancer[J]. Ann Surg Oncol,2012,19(3):728-733.

[28 ]Gilmo re DM, Khull a r OV, J a klit sch MT,

Chirieac LR, Frangioni JV, Colson YL. Identification of

metastatic nodal disease in a phase 1 dose-escalation trial of

intraoperative sentinel lymph node mapping in non-small cell

lung cancer using near-infrared imaging. J Thorac Cardiovasc

Surg. 2013; 146(3): 562-570.

[29]C.S. Digesu, K.J. Hachey, D.M. Gilmore, et al.

Long-term outcomes after near-infrared sentinel lymph node

mapping in non-small cell lung cancer.J Thorac Cardiovasc

Surg, 155 (3) (2018), pp. 1280-1291.

[30]Yuasa Y, Seike J, Yoshida T, et al. Sentinel

lymph node biopsy using intraoperative indocyanine green

fluorescence imaging navigated with preoperative CT

lymphography for superficial esophageal cancer. Ann Surg

Oncol. 2012; 19(2): 486-493.

[31]F. Schlottmann, A. Barbetta, B. Mungo, A.O. Lidor,

D. Molena.Identification of the lymphatic drainage pattern of

esophageal cancer with near-infrared fluorescent imaging.J

Laparoendosc Adv Surg Tech, 27 (3) (2017), pp. 268-271.

161

现代医学前沿 | 第2卷/第12期

Advances in Mordern Medical

[32]M.K. Jung, M. Cho, C.K. Roh, et al. Assessment

of diagnostic value of fluorescent lymphography-guided

lymphadenectomy for gastric cancer.Gastric Cancer, 24 (2)

(2021), pp. 515-525.

[33]N. Yokota, T. Go, Y. Otsuki, S.S. Chang, N.

Misaki, H. Yokomise.A new method to identify air leaks after

pulmonary resection using indocyanine green aerosol.Ann

Thorac Surg., 114 (6) (2022), pp. 2067-2072.

[34]K. Koyanagi, S. Ozawa, Y. Ninomiya, et al.

Association between indocyanine green fluorescence blood

flow speed in the gastric conduit wall and superior mesenteric

artery calcification: predictive significance for anastomotic

leakage after esophagectomy.Esophagus, 18 (2) (2021), pp.

248-257.

[35]Keita Nakanishi, Yuka Kadomatsu, Harushi Ueno,

et al. Complete visualization using indocyanine green in

thoracic surgery for pulmonary sequestration.J Thorac Dis

2023;15(10):5714-5722.

[36]PREDINA J D,KEATING J,NEWTON A,et al. A

clinical trial of intraoperative near-infrared imaging to assess

tumor extent and identify residual disease during anterior

mediastinal tumor resection[J]. Cancer,2019,125(5):807-817.

[37]G. Pei, Y. Liu, Q. Liu, et al. The safety and

feasibility of intraoperative near-infrared fluorescence imaging

with indocyanine green in thoracoscopic sympathectomy for

primary palmar hyperhidrosis.Thorac Cancer, 11 (4) (2020),

pp. 943-949.

[38]G.T. Kennedy, F.S. Azari, E. Bernstein, et al. Firstin-human results of targeted intraoperative molecular imaging

for visualization of ground glass opacities during robotic

pulmonary resection.Transl Lung Cancer Res, 11 (8) (2022),

pp. 1567-1577


Refbacks

  • 当前没有refback。